Immuno-Diagnosis

Current mainstream immunodiagnostic methods include chemiluminescence immunoassay, latex immunoturbidimetry, and immunochromatography. We can provide a diverse range of key raw materials, such as magnetic microspheres, latex microspheres, and time-resolved microspheres, capable of meeting application needs.


图片4.png


1. Chemiluminescence Immunoassay

Self-developed Anti-CA153-093 mAb (Cat. No.: BP0011) was conjugated toCarboxyl-Activated MagPoly Beads (Cat. No.: MP1201) using a two-step method. Key performance evaluations, including reaction kinetics, precision, and clinical correlation, were conducted in an acridinium ester direct chemiluminescence system (Instrument: Yingkai 12910).


图片2.jpg

Figure 1 Research on the performance of Carboxyl-Activated MagPoly Beads (Take the CA153 project as an example)


2. Latex Immunoturbidimetry

Various antibodies were modified onto different latex microsphere products (developed independently by BioG) via activation, conjugation, and blocking steps. Reactivity was assessed on a fully automated biochemical analyzer (Instrument: Hitachi 7180).


cTnI

Figure 2.1 Detection range: 0.5-25.0ng/ml

PCT

Figure 2.1 Detection range: 0.2-25.0ng/ml

D-dimer

Figure 2.3 Detection range: 0.2-20.0μg/ml


3. Immunochromatographic Assay

Depending on your application direction and specific needs, carriers such as colloidal gold, time-resolved microspheres, or fluorescent microspheres can be selected for protein/antibody conjugation and modification to qualitatively or semi-quantitatively evaluate raw material performance.


图片1.jpg

· Ordering Information
Product NameCatalog NumberDiameter (nm)Solid ContentApplications
Carboxyl-Activated MagPoly BeadsMP1201100010mg/mlChemiluminescence Platform, Capture & Purification Applications
MP1202280010mg/ml
Streptavidin Magpoly BeadsMP0601100010mg/ml
MP0602280010mg/ml
NHS-Activated MagPoly BeadsMP0701100010mg/ml
Tosyl-Activated MagPoly BeadsMP0503280010mg/ml
Epoxy-Activated MagPoly BeadsMP1101100010mg/ml
Amino-Activated Magpoly BeadsMP0201100010mg/ml
Carboxyl Polystyrene LatexBL10112012010%Latex Immunoturbidimetry Platform
BL101150150
BL101200200
BL101250250
BL101300300
Nano Colloidal GoldGN010120-500.04%Immunochromatography Platform
Colloidal Gold Polymer GP010120010mg/ml
Colloidal Gold Magpoly BeadsGM010120010mg/ml
30010mg/ml
50010mg/ml
Time-resolved Fluorescence MicrosphereBL1052002001%
BL105250250
BL105300300
Green Fluorescence MicrosphereBL1072002001%
BL107300300
BL107400400

Get In Touch With Us